BRING SHIP FROM DEAD CONDITION TO LIVE CONDITION
BRING SHIP FROM DEAD CONDITION TO LIVE CONDITION
1. DEAD SHIP CONDITION
|
|
2. SHORE SUPPLY AVAILABLE
ESTABLISH SHORE SUPPLY.
CHECK PHASE SEQUENCE, VOLTAGE AND FREQUENCY.
|
2. NO SHORE SUPPLY AVAILABLE
ENSURE EMERGENCY GENERATOR DO TANK LEVEL IS ADEQUATE
|
3. SUPPLY MAIN SWITCHBOARD
|
3. START EMERGENCY GENERATOR
|
4. (a) ISOLATE SEQUENTIAL RESTART SYSTEM
(b) ALL ANCILLARY EQUIPMENT SET MANUAL TO AVOID
(c) LOW-PRESSURE AUTO START
(d) SUPPLY 440V, 220V EMERGENCY SWITCHBOARD
|
|
5. PREPARE CENTRAL FW COOLING SYSTEM, START CENTRAL COOLING WATER PUMP.
|
|
6. START GENERATOR LUB OIL PRIMING PUMP
|
|
7. START AIR COMPRESSOR AND TOP UP AIR RESERVOIR
|
|
8. START DO FLUSHING PUMP
|
|
9. (a) PREPARE DIESEL GENERATOR TO START
(b) START DIESEL GENERATOR
|
|
10. (a) PREPARE SW COOLING SYSTEM
(b) START SW COOLING SYSTEM
|
|
11. (a) DISCONNECT SHORE SUPPLY
(b) SUPPLY POWER TO 220V & 440V MAIN SWITCHBOARD
(c) SUPPLY POWER TO 220V & 440V EMERGENCY SWITCHBOARD
|
|
12. START UP CONTROL AIR SYSTEM
|
|
13. PLACE EMERGENCY GENERATOR ON STANDBY
|
|
14. RESET PREFERENTIAL TRIPS
|
|
15. (a) START E/R & ACCOMMODATION VENTILATION FANS.
(b) START AIR CONDITIONING PLANT.
|
|
16. ENSURE CO2 SYSTEM IS READY TO USE
|
|
17. (a) PUT WATER FOG SYSTEM IN OPERATION
(b) PRESSURISE MAIN FIRE LINE
|
|
18. START DOMESTIC FW SYSTEM WITH ELECTRIC HEATER IN USE
|
|
19. PUT DOMESTIC REFRIGERATION SYSTEM INTO OPERATION
|
|
20. PUT GENERAL SERVICE AIR SYSTEM INTO OPERATION
|
|
21. PUMP BILGES TO BILGE TANK AS REQUIRED
|
|
22. (a) PUT ALL ANCILLARY EQUIPMENT ON STANDBY
(b) RESTORE SEQUENTIAL RESTART SYSTEM
(c) PUT REMAINING DIESEL GENERATORS ON STANDBY
|
|
23. PLANT IS NOW IN LIVE CONDITION
|
|