BRING SHIP FROM MANOEUVRING CONDITION TO FULL AWAY CONDITION

BRING SHIP FROM MANOEUVRING CONDITION TO FULL AWAY CONDITION

1. MANOEUVRING CONDITION
     2. (a) TWO DIESEL GENERATORS IN USE
   (b) OTHER DIESEL GENERATORS ON STANDBY
   (c) EMERGENCY GENERATOR ON STANDBY
   (d) BOILER AND STEAM SYSTEM IN USE
   (e) DIESEL GENERATOR RUNNING ON HFO
   (f) M/E JCW SYSTEM IN WARM CONDITION
   (g) M/E CIRCULATING WITH HFO
   (h) STEERING MOTORS RUNNING
   (i) DECK MACHINERY READY FOR USE
     3. PUT M/E ON AUTO RUN UP PROGRAM
     4. SHUT DOWN THE M/E JCW HEATING SYSTEM
     5. STOP THRUSTERS
     6. ONLY ONE GENERATOR SHOULD BE RUNNING
     7. START FWG SYSTEM
     8. ENSURE AUX BOILER STOPS ONCE THE EXH BOILER TAKES OVER STEAM GENERATION
9. PLANT IS NOW IN FULL AWAY CONDITION