STARTING & STOPPING OF FRESH WATER GENERATOR ON BOARD

STARTING OF FRESH WATER GENERATOR 

  • Open ejector suction valve
  • Open overboard valve 
  • Start F.W. Generator Ejector pump
  • Close vacuum breakers
  • Wait for sufficient vacuum (about  92%)
  • Slowly open J.C.W inlet and outlet valve
  • Slowly close J.C.W. by-pass valve till evaporator shell temprature is reaching a body temperature of +/- 45-50 degree centigrade
  • Open ball valve  on sterilizer and start the unit
  • If you see fresh water in the inspection glass, start distillate pump
  • Open chemical dosing valves
  • Switch on Salinity Controller Alarm
  • Check level of drinking water tanks

STOPPING OF FRESH WATER GENERATOR
  • Switch off Salinity Controller Alarm
  • Switch off distillate pump
  • Close chemical dosing valve on dosing unit
  • Stop the sterilizer and close the ball valve
  • Slowly open J.C.W by pass valve completely
  • Slowly close J.C.W inlet and outlet valve
  • Open vacuum breakers
  • Cooling down of the evaporator for a 30mins
  • Stop the ejector pump
  • Close overboard valve
  • Close ejector suction valve