STARTING & STOPPING OF FRESH WATER GENERATOR ON BOARD
STARTING OF FRESH WATER GENERATOR
- Open ejector suction valve
- Open overboard valve
- Start F.W. Generator Ejector pump
- Close vacuum breakers
- Wait for sufficient vacuum (about 92%)
- Slowly open J.C.W inlet and outlet valve
- Slowly close J.C.W. by-pass valve till evaporator shell temprature is reaching a body temperature of +/- 45-50 degree centigrade
- Open ball valve on sterilizer and start the unit
- If you see fresh water in the inspection glass, start distillate pump
- Open chemical dosing valves
- Switch on Salinity Controller Alarm
- Check level of drinking water tanks
STOPPING OF FRESH WATER GENERATOR
- Switch off Salinity Controller Alarm
- Switch off distillate pump
- Close chemical dosing valve on dosing unit
- Stop the sterilizer and close the ball valve
- Slowly open J.C.W by pass valve completely
- Slowly close J.C.W inlet and outlet valve
- Open vacuum breakers
- Cooling down of the evaporator for a 30mins
- Stop the ejector pump
- Close overboard valve
- Close ejector suction valve